{"id":69644,"date":"2026-03-11T11:22:21","date_gmt":"2026-03-11T11:22:21","guid":{"rendered":"https:\/\/fdalab.am\/?post_type=cpt_services&#038;p=69644"},"modified":"2026-03-19T11:40:11","modified_gmt":"2026-03-19T11:40:11","slug":"fertilizer","status":"publish","type":"cpt_services","link":"https:\/\/fdalab.am\/?cpt_services=fertilizer&lang=en","title":{"rendered":"Fertilizer"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"69644\" class=\"elementor elementor-69644\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-467c7343 elementor-section-boxed elementor-section-height-default elementor-section-height-default sc_fly_static\" data-id=\"467c7343\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-extended\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2c8728ac sc_content_align_inherit sc_layouts_column_icons_position_left sc_fly_static\" data-id=\"2c8728ac\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div data-animation-type=\"block\" class=\"elementor-element elementor-element-23cdc8db elementor-widget__width-initial animated-slow animation_type_block sc_fly_static elementor-invisible elementor-widget elementor-widget-trx_sc_title\" data-id=\"23cdc8db\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"trx_sc_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div\t\tclass=\"sc_title sc_title_default\" ><h1 class=\"sc_item_title sc_title_title sc_item_title_style_default sc_item_title_tag trx_addons_inline_1556886928\"\n\t\t\t><span class=\"sc_item_title_text\">Laboratory Testing of Fertilizers<\/span><\/h1><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-548568af elementor-section-full_width elementor-section-height-default elementor-section-height-default sc_fly_static\" data-id=\"548568af\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-extended\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-4a9020b2 sc_content_align_inherit sc_layouts_column_icons_position_left sc_fly_static\" data-id=\"4a9020b2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div data-animation-type=\"block\" class=\"elementor-element elementor-element-4d48df92 no-title animation_type_block sc_fly_static elementor-invisible elementor-widget elementor-widget-image\" data-id=\"4d48df92\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;marveland-fadeinup&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"711\" src=\"https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/1.png\" class=\"attachment-full size-full wp-image-67154\" alt=\"\" srcset=\"https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/1.png 1024w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/1-300x208.png 300w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/1-768x533.png 768w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/1-370x257.png 370w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/1-840x583.png 840w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/1-410x285.png 410w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8fcd35 sc_fly_static elementor-widget elementor-widget-spacer\" data-id=\"3e8fcd35\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div data-animation-type=\"block\" class=\"elementor-element elementor-element-7b41fd73 elementor-widget__width-initial animated-slow animation_type_block sc_fly_static elementor-invisible elementor-widget elementor-widget-trx_sc_title\" data-id=\"7b41fd73\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"trx_sc_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div\t\tclass=\"sc_title sc_title_default\" ><h2 class=\"sc_item_title sc_title_title sc_item_title_style_default sc_item_title_tag trx_addons_inline_1544930481\"\n\t\t\t><span class=\"sc_item_title_text\">Objective of Laboratory Testing<\/span><\/h2><div class=\"sc_item_descr sc_title_descr\"><p>\u2018\u2019FDA Laboratory\u2019\u2019 LLC conducts laboratory testing of fertilizers within the scope of its accreditation, in accordance with the applicable Technical Regulations of the Customs Union. The purpose of fertilizer testing is to ensure the safety of fertilizers and to support their safe use and continued circulation.<\/p>\n<\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-5f558e93 sc_content_align_inherit sc_layouts_column_icons_position_left sc_fly_static\" data-id=\"5f558e93\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d09528e elementor-widget-tablet__width-initial sc_fly_static elementor-widget elementor-widget-trx_widget_custom_links\" data-id=\"d09528e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"trx_widget_custom_links.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"widget_area sc_widget_custom_links\"><aside class=\"widget widget_custom_links\"><ul class=\"custom_links_list\"><li class=\"custom_links_list_item with_icon\"><span class=\"custom_links_list_item_link\"><span\t\t\t\t\t\t\tclass=\"custom_links_list_item_icon sc_icon_type_icons icon-newspaper\"\n\t\t\t\t\t\t><\/span><span class=\"custom_links_list_item_title\">Testing Regulation: <\/span><\/span><span class=\"custom_links_list_item_description\">Decision No. 1692-N of the Government of the Republic of Armenia<\/span><\/li><li class=\"custom_links_list_item custom_links_list_item_label_hover with_icon\"><span class=\"custom_links_list_item_link\"><span\t\t\t\t\t\t\tclass=\"custom_links_list_item_icon sc_icon_type_icons icon-clock-empty\"\n\t\t\t\t\t\t><\/span><span class=\"custom_links_list_item_title\">Testing Duration: <\/span><span class=\"custom_links_list_item_label\">The duration of testing depends on various factors. It is recommended to contact the laboratory in advance prior to submitting samples.<\/span><\/span><span class=\"custom_links_list_item_description\">7 Days<\/span><\/li><li class=\"custom_links_list_item with_icon\"><span class=\"custom_links_list_item_link\"><span\t\t\t\t\t\t\tclass=\"custom_links_list_item_icon sc_icon_type_icons icon-shopping-paper-bag-\"\n\t\t\t\t\t\t><\/span><span class=\"custom_links_list_item_title\">Issued Document: <\/span><\/span><span class=\"custom_links_list_item_description\">Test Report<\/span><\/li><\/ul><\/aside><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ad828cb sc_fly_static elementor-widget elementor-widget-spacer\" data-id=\"7ad828cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div data-animation-type=\"block\" class=\"elementor-element elementor-element-3befaebc no-title animation_type_block sc_fly_static elementor-invisible elementor-widget elementor-widget-image\" data-id=\"3befaebc\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;marveland-fadeinup&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2.png\" class=\"attachment-full size-full wp-image-67155\" alt=\"\" srcset=\"https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2.png 1024w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2-300x300.png 300w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2-150x150.png 150w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2-768x768.png 768w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2-370x370.png 370w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2-120x120.png 120w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2-840x840.png 840w, https:\/\/fdalab.am\/wp-content\/uploads\/2025\/07\/2-410x410.png 410w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2f3944c8 elementor-section-full_width elementor-section-height-default elementor-section-height-default sc_fly_static\" data-id=\"2f3944c8\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-extended\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-866b592 sc_content_align_inherit sc_layouts_column_icons_position_left sc_fly_static\" data-id=\"866b592\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div data-animation-type=\"block\" class=\"elementor-element elementor-element-1ef1fb02 elementor-widget__width-inherit animated-slow elementor-widget-tablet__width-initial animation_type_block sc_fly_static elementor-invisible elementor-widget elementor-widget-trx_sc_title\" data-id=\"1ef1fb02\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"trx_sc_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div\t\tclass=\"sc_title sc_title_default\" ><h2 class=\"sc_item_title sc_title_title sc_item_title_style_default sc_item_title_tag trx_addons_inline_1178929381\"\n\t\t\t><span class=\"sc_item_title_text\">Key Test Parameters<\/span><\/h2><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7036162a sc_fly_static elementor-widget elementor-widget-trx_sc_icons\" data-id=\"7036162a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"trx_sc_icons.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div \tclass=\"sc_icons sc_icons_modern sc_icons_size_medium sc_align_left\" ><div class=\"sc_icons_item\"><div class=\"sc_icons_item_details\"><h4 class=\"sc_icons_item_title\"><span>CHEMICAL PARAMETERS<\/span><\/h4><div class=\"sc_icons_item_description\"><span>\u2022 Determination of Potassium (K) Content<\/span><span>\u2022 Determination of Calcium (Ca) Content<\/span><span>\u2022 Determination of Moisture Content<\/span><span>\u2022 Determination of Phosphorus (P) Content<\/span><span>\u2022 Determination of Protein Content<\/span><span>\u2022 Determination of Nitrogen (N) Content<\/span><span>\u2022 Determination of Sulfur (S) Content<\/span><span>\u2022 Determination of Zinc (Zn) Content<\/span><span>\u2022 Determination of Copper (Cu) Content<\/span><span>\u2022 Determination of Manganese (Mn) Content<\/span><span>\u2022 Determination of Molybdenum (Mo) Content<\/span><span>\u2022 Other Relevant Parameters<\/span><\/div><\/div><\/div><\/div><!-- \/.sc_icons -->\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5d3ad817 elementor-section-full_width elementor-section-height-default elementor-section-height-default sc_fly_static\" data-id=\"5d3ad817\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-extended\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ad71cd9 sc_content_align_inherit sc_layouts_column_icons_position_left sc_fly_static\" data-id=\"ad71cd9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div data-animation-type=\"block\" class=\"elementor-element elementor-element-6757e46d elementor-widget__width-initial animated-slow animation_type_block sc_fly_static elementor-invisible elementor-widget elementor-widget-trx_sc_title\" data-id=\"6757e46d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"trx_sc_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div\t\tclass=\"sc_title sc_title_default\" ><h2 class=\"sc_item_title sc_title_title sc_item_title_style_default sc_item_title_tag trx_addons_inline_401284262\"\n\t\t\t><span class=\"sc_item_title_text\">Provision of Test Results<\/span><\/h2><div class=\"sc_item_descr sc_title_descr\"><p>Based on the test results, the laboratory issues an official test report.<\/p>\n<\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-67533b2d sc_content_align_inherit sc_layouts_column_icons_position_left sc_fly_static\" data-id=\"67533b2d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div data-animation-type=\"block\" class=\"elementor-element elementor-element-74df0bf7 elementor-widget__width-initial animated-slow animation_type_block sc_fly_static elementor-invisible elementor-widget elementor-widget-trx_sc_title\" data-id=\"74df0bf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"trx_sc_title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div\t\tclass=\"sc_title sc_title_default\" ><h2 class=\"sc_item_title sc_title_title sc_item_title_style_default sc_item_title_tag trx_addons_inline_1284665324\"\n\t\t\t><span class=\"sc_item_title_text\">Declaration Process<\/span><\/h2><div class=\"sc_item_descr sc_title_descr\"><p>The laboratory test report issued by \u201cFDA Laboratory\u201d LLC is an official document that enables the organization of the product declaration process.<br \/>\n\u201cFDA Laboratory\u201d LLC cooperates with the Product Certification Body of \u201cCertification and Quality\u201d LLC, which, within the scope of its accreditation, issues Technical Regulation (AST) Declarations of Conformity.<\/p>\n<p>For further details regarding the certification process, please call +374 96 35 00 01.<\/p>\n<\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c78a9b6 elementor-section-boxed elementor-section-height-default elementor-section-height-default sc_fly_static\" data-id=\"c78a9b6\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;slideshow&quot;,&quot;background_slideshow_gallery&quot;:[],&quot;background_slideshow_loop&quot;:&quot;yes&quot;,&quot;background_slideshow_slide_duration&quot;:5000,&quot;background_slideshow_slide_transition&quot;:&quot;fade&quot;,&quot;background_slideshow_transition_duration&quot;:500}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-extended\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c1d886f sc_content_align_inherit sc_layouts_column_icons_position_left sc_fly_static\" data-id=\"c1d886f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-daf1e1b sc_fly_static elementor-widget elementor-widget-trx_sc_button\" data-id=\"daf1e1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"trx_sc_button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div\tclass=\"sc_item_button sc_button_wrap sc_align_center\" ><a href=\"https:\/\/fdalab.am\/?page_id=69246&#038;lang=en\" class=\"sc_button sc_button_default sc_button_size_normal sc_button_icon_left color_style_link2\" ><span class=\"sc_button_text\"><span class=\"sc_button_title\">CONTACT US<\/span><\/span><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Laboratory Testing of Fertilizers Objective of Laboratory Testing \u2018\u2019FDA Laboratory\u2019\u2019 LLC conducts laboratory testing of&hellip;<\/p>\n","protected":false},"author":1,"featured_media":67154,"comment_status":"open","ping_status":"closed","template":"elementor_header_footer","cpt_services_group":[428],"class_list":["post-69644","cpt_services","type-cpt_services","status-publish","has-post-thumbnail","hentry","cpt_services_group-gyuxtnt-en"],"_links":{"self":[{"href":"https:\/\/fdalab.am\/index.php?rest_route=\/wp\/v2\/cpt_services\/69644","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fdalab.am\/index.php?rest_route=\/wp\/v2\/cpt_services"}],"about":[{"href":"https:\/\/fdalab.am\/index.php?rest_route=\/wp\/v2\/types\/cpt_services"}],"author":[{"embeddable":true,"href":"https:\/\/fdalab.am\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fdalab.am\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=69644"}],"version-history":[{"count":7,"href":"https:\/\/fdalab.am\/index.php?rest_route=\/wp\/v2\/cpt_services\/69644\/revisions"}],"predecessor-version":[{"id":70609,"href":"https:\/\/fdalab.am\/index.php?rest_route=\/wp\/v2\/cpt_services\/69644\/revisions\/70609"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fdalab.am\/index.php?rest_route=\/wp\/v2\/media\/67154"}],"wp:attachment":[{"href":"https:\/\/fdalab.am\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=69644"}],"wp:term":[{"taxonomy":"cpt_services_group","embeddable":true,"href":"https:\/\/fdalab.am\/index.php?rest_route=%2Fwp%2Fv2%2Fcpt_services_group&post=69644"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}